Nidec Leroy-Somer: Terms and Definitions

This section contains terms and definitions related to Nidec Leroy-Somer generators and alternators. KTS Engineering is a certified Nidec service partner in Ukraine, providing supply, maintenance, rewinding and major overhauls of Leroy-Somer generators.

The Brand and KTS Engineering's Status

Nidec Leroy-Somer

Nidec Leroy-Somer - a French manufacturer of synchronous generators and alternators for industrial gas engine gensets and gas turbines. Founded in 1919 in Angoulême, France; since 2017 it has been part of the Japanese Nidec Corporation group. Leroy-Somer generators are supplied with INNIO Jenbacher and Waukesha gas engines and other industrial prime movers. The power range is 30 kW to 20 MW.

Synonyms: Leroy-Somer · LS · Nidec LS · Leroy-Somer alternators

KTS Engineering - Certified Nidec Partner

KTS Engineering as a certified Nidec partner - the authorized Nidec Leroy-Somer service partner in Ukraine. The company supplies new Leroy-Somer generators and provides maintenance, winding rewinds, major overhauls, rotor balancing, insulation testing and bearing replacement. KTS Engineering services Leroy-Somer generators installed in Jenbacher cogeneration plants and with other prime movers.

Generator Design

Synchronous Generator

Synchronous generator - an electrical machine that produces alternating current whose frequency is rigidly linked to the rotor speed. Gas engine gensets and gas turbine units use synchronous generators: at a grid frequency of 50 Hz, the speed is 1,500 rpm (for a 4-pole generator). Leroy-Somer produces brushless synchronous generators and generators with PMG excitation.

Synonyms: alternator · brushless generator · AC generator

Brushless Generator

Brushless generator - a type of synchronous generator that uses a rotating rectifier instead of brush contacts to supply excitation current to the rotor. This eliminates sliding contacts and the brush gear - the main source of wear and maintenance in conventional generators. Brushless design is standard for Leroy-Somer generators supplied with Jenbacher cogeneration plants.

Related terms: PMG · excitation system

Stator

Stator - the stationary part of a synchronous generator, in whose windings the generated electric current is induced. It consists of a stack of electrical steel laminations and a three-phase stator winding placed in the core slots. The insulation class of the stator winding determines the maximum permissible temperature rise and therefore the permissible generator load at a given ambient temperature.

Related terms: insulation class · generator rewinding

Rotor

Rotor - the rotating part of a synchronous generator that creates the magnetic field inducing the EMF in the stator winding. The rotor of a synchronous generator is either a salient-pole design (low speed, 4-pole for 50 Hz / 1,500 rpm) or a non-salient-pole (cylindrical) design (high speed, 2-pole for 50 Hz / 3,000 rpm). The rotor carries the field winding, which is supplied by the AVR system via a rotating rectifier.

Related terms: rotor balancing · stator

Excitation System

Excitation system - the set of components that create and control the magnetic flux in the generator rotor. It includes the exciter (a small auxiliary generator on the same shaft as the rotor), a rotating rectifier and an automatic voltage regulator (AVR). Excitation power is taken from a PMG or from the generator terminals; the AVR control signal keeps the voltage at the generator terminals constant regardless of load.

PMG (Permanent Magnet Generator)

PMG (Permanent Magnet Generator) - an auxiliary generator mounted on the rotor shaft of the main Leroy-Somer generator. The PMG provides a stable power supply for the AVR regardless of the main generator's load current. This ensures stable voltage control during sudden load changes and short circuits, when the voltage at the generator terminals can drop to zero. The PMG version is the recommended standard for generators in cogeneration plants.

AVR (Automatic Voltage Regulator)

AVR (Automatic Voltage Regulator) - the electronic control unit of the generator's excitation system. It continuously compares the generator's actual output voltage with the setpoint and adjusts the excitation current to maintain rated voltage as load and speed change. The Leroy-Somer AVR maintains voltage within ±1% for load changes from 0 to 100%. KTS Engineering supplies Leroy-Somer AVRs as spare parts.

Insulation Class H / F

Insulation class - an IEC-standardized rating that defines the maximum permissible temperature of the generator windings in continuous operation. Class F - maximum winding temperature 155°C; class H - 180°C. Leroy-Somer generators for cogeneration plants are usually made with class H insulation (higher permissible operating temperature), which allows them to operate at elevated ambient temperatures without derating.

Degree of Protection IP23 / IP44 / IP55

IP degree of protection (Ingress Protection) - an IEC-standardized rating of how well the generator enclosure is protected against the ingress of solid objects (first digit) and water (second digit). IP23 - protection against solid objects larger than 12 mm and against water spraying up to 60° from vertical; used for generators installed indoors. IP44 - protection against solid objects larger than 1 mm and against water splashing from any direction. IP55 - dust protection and protection against water jets; used for generators in containerized units.

Coupling (Engine-Generator Connection)

Coupling - the element connecting the gas engine shaft to the generator shaft. It transmits torque and compensates for minor misalignment. Jenbacher-Leroy-Somer gensets use flexible couplings with rubber elements to damp the engine's torsional vibration. Correct coupling selection and its technical condition affect the vibration level of the unit and the service life of the generator bearings.

Generator Parameters

Generator Rated Power (kW / kVA)

Generator rated power - the maximum continuous load of the generator specified by the manufacturer under standard conditions (40°C ambient temperature, rated voltage and power factor). It is given in two values: kW (active power) and kVA (apparent power). For example, the Leroy-Somer generator for the Jenbacher J624: 4,500 kW / 5,000 kVA at cosφ = 0.9.

Related terms: active power · apparent power

Rated Voltage (400 V / 6.3 kV / 10.5 kV)

Generator rated voltage - the standard output voltage at the generator terminals at rated load. For genset generators up to 2 MW, the standard is 400 V (0.4 kV), stepped up by a transformer. For larger units of 2-5 MW, a direct output at 6.3 kV or 10.5 kV reduces currents and simplifies the electrical layout. Leroy-Somer produces generators for all three voltage levels.

Power Factor cosφ

Power factor (cosφ) - the ratio of a generator's active power to its apparent power. It defines the share of apparent power that actually does useful work. At cosφ = 1.0, all the power generated is active. In practice, industrial loads are inductive (electric motors, transformers); a typical cosφ is 0.8-0.9. Leroy-Somer generators control cosφ via the AVR.

Active Power (kW)

Active power (kW) - the power that does useful work: driving motors, heating, lighting. For a generator: P = S × cosφ, where S is the apparent power in kVA. Active power alone determines the fuel consumption of the gas engine.

Related terms: reactive power · apparent power · cosφ

Reactive Power (kvar)

Reactive power (kvar) - the power needed to create magnetic and electric fields in inductive and capacitive loads (electric motors, transformers). Reactive power does no useful work but places a current load on the generator. A Leroy-Somer generator produces or absorbs reactive power depending on its excitation level: in over-excited mode the generator produces Q (capacitive load on the grid); in under-excited mode it absorbs Q (inductive load).

Apparent Power (kVA)

Apparent power (kVA) - the vector sum of active and reactive power: S = √(P² + Q²). It determines the thermal load on the windings and magnetic circuit of the generator and is the main criterion for sizing a generator. Leroy-Somer nameplate ratings are always given in kVA at a specified cosφ (usually 0.8 or 0.9).

Leroy-Somer Service

Leroy-Somer Generator Rewinding

Leroy-Somer generator rewinding - restoration or replacement of stator and/or rotor windings damaged by inter-turn short circuits, insulation breakdown to ground, overheating or mechanical damage. KTS Engineering performs rewinding using genuine Leroy-Somer winding wire and impregnating varnishes. After rewinding, an insulation test and a load test are carried out. Rewinding a generator is significantly cheaper than buying a new one.

Generator Rotor Balancing

Generator rotor balancing - elimination of rotor imbalance, i.e. an uneven mass distribution that causes unit vibration and increased bearing loads. It is performed on a dynamic balancing machine after rewinding or bearing replacement. Permissible vibration levels after balancing are specified by ISO 1940-1 (grade G2.5 for industrial generators).

Generator Insulation Testing

Generator insulation testing - checking the condition of the winding insulation by measuring insulation resistance (with a 500-5,000 V megohmmeter) and the absorption ratio (R60/R15). The normal insulation resistance for Leroy-Somer generators is at least 1 MΩ per 1 kV of rated voltage. The test is performed at every scheduled maintenance, after a long shutdown and before returning the unit to service.

Generator Bearing Replacement

Generator bearing replacement - scheduled or emergency replacement of the rotor bearings of a Leroy-Somer generator. Generator bearings operate under constant load and must be replaced every 20,000-40,000 hours depending on the bearing type and operating conditions. Signs of wear include increased vibration and noise and a bearing housing temperature above normal. KTS Engineering uses OEM-supplied bearings.

Leroy-Somer Generator Upgrades

Leroy-Somer generator upgrades - updating outdated excitation system components: replacing an old AVR with a modern digital regulator, converting from a brush-type excitation system to a brushless one, and integrating with modern PLC control systems or myPlant. This significantly improves voltage control quality without replacing the entire generator.