myPlant: Terms and Definitions
This section contains terms and definitions related to INNIO myPlant – the remote monitoring and predictive diagnostics system for Jenbacher and Waukesha gas engine gensets. KTS Engineering connects and services customer units via myPlant under CSA contracts.
The myPlant Platform
- myPlant
myPlant - INNIO's cloud platform for remote monitoring and control of Jenbacher and Waukesha gas engine gensets. It provides round-the-clock real-time monitoring of more than 300 engine operating parameters, predictive diagnostics, alarm notifications and remote access to the DIA.NE controller. It is available in a web browser and as an iOS/Android mobile app. KTS Engineering connects all new Jenbacher units to myPlant under CSA contracts.
Synonyms: INNIO myPlant · myPlant APM · Jenbacher monitoring platform
- myPlant APM (Asset Performance Management)
myPlant APM (Asset Performance Management) - the asset performance management module of the myPlant platform. APM analyzes historical data and parameter trends using machine learning algorithms to detect anomalies and predict failures. Its output is scheduled maintenance recommendations and warnings that intervention is needed before a failure occurs.
Synonyms: myPlant APM · predictive analytics module
- Cloud Monitoring Platform
Cloud monitoring platform - the architecture of myPlant: data from the DIA.NE controller is transmitted over a secure, encrypted channel to INNIO servers (Microsoft Azure cloud). The customer and KTS Engineering access the data through a browser or the app without installing any additional software. The full history for the entire operating life of the unit is stored.
- myPlant Mobile App (iOS / Android)
myPlant mobile app - the client app of the myPlant platform for iOS and Android smartphones and tablets. It lets the operator or company management check the condition of the unit, receive push notifications about alarm events, and view current parameters and operating reports anytime, anywhere. It supports managing several units at once.
- Fleet Map
Fleet map - a myPlant function that shows all connected units of a customer or of KTS Engineering on a geographic map, with the current status of each: running, under maintenance, or tripped. It allows KTS Engineering engineers to quickly identify problem sites and prioritize service visits. Available in the browser and in the mobile app.
Monitoring and Diagnostics
- 24/7 Real-Time Monitoring
24/7 real-time monitoring - continuous transmission of more than 300 unit operating parameters from the DIA.NE controller to the myPlant platform, with data refresh intervals from 1 second to several minutes. It covers temperatures (coolant, oil, exhaust gas), pressures (oil, gas, boost), vibration, exhaust gas composition, output, speed and protection status. Data is archived for the entire operating life of the unit.
- Predictive Maintenance
Predictive maintenance (predictive diagnostics) - a maintenance approach in which the decision to repair or replace a component is based on the actual condition of the equipment rather than a fixed schedule. myPlant APM analyzes parameter trends and detects deviations several days before a possible failure. KTS Engineering uses predictive diagnostics data to plan service visits and part replacements proactively, reducing unplanned downtime of customer units.
Synonyms: predictive diagnostics · PdM · Condition-Based Maintenance
- Remote Access to the DIA.NE Controller
Remote access to the DIA.NE controller - a myPlant function that allows an authorized KTS Engineering or INNIO engineer to access the DIA.NE controller interface over a secure, encrypted channel without visiting the site. It makes it possible to view current parameters and the alarm log, change setpoints and settings, and restart the unit after an alarm has been cleared. Access is granted only with the customer's permission.
- Alarm Notifications (Email / SMS)
Alarm notifications - automatic myPlant messages sent by email and SMS when an alarm occurs, a setpoint is exceeded or a diagnostic warning is raised. They are configured individually: the plant operator receives the full set of notifications, management receives only critical alarms, and the KTS Engineering duty engineer receives all events from units serviced under a CSA contract. Notifications include the error code, a description of the situation and recommendations.
- Automatic Operating Reports
Automatic operating reports - periodic reports (daily, weekly, monthly) generated by myPlant for each unit: electricity output, heat output, total operating hours, number of starts, utilization factor and a list of alarm events. KTS Engineering uses the reports to monitor compliance with the terms of the CSA contract and to analyze the economic performance of the customer's cogeneration plant.
- Operating Hours Analysis and Maintenance Planning
Operating hours analysis and maintenance planning - a myPlant function for tracking operating hours accumulated since the last maintenance. The system automatically notifies KTS Engineering when a unit is approaching its next scheduled maintenance (according to the CSA schedule). This makes it possible to order the necessary spare parts in advance and agree the shutdown dates with the customer, so the unit never runs beyond its maintenance interval.
Related terms: operating hour · TBO · CSA
- Oil Analysis Integration
Oil analysis integration - an optional myPlant module that allows laboratory oil analysis results to be uploaded directly to the platform and displayed alongside operating parameter trends. This gives a complete picture of the engine's condition: laboratory data (TBN, viscosity, wear metals) plus online parameters (temperature, pressure, vibration). The integration helps to identify correlations between oil parameters and engine operating parameters.
Monitored Parameters
- Coolant Temperature Monitoring
Coolant temperature monitoring - continuous monitoring via myPlant of the temperature in the engine's HT and LT circuits. A deviation of the HT circuit temperature from normal (90-95°C) indicates a faulty thermostat or water pump, or a clogged cooling system. myPlant records temperature trends and warns of deviations before the alarm setpoint is reached.
- Oil Pressure Monitoring
Oil pressure monitoring - continuous monitoring of the pressure in the engine lubrication system. Oil pressure below normal (typically 3.5-5.5 bar at rated speed for Jenbacher) indicates a clogged filter, low oil level, a worn oil pump or a leak. A drop in pressure to the alarm setpoint causes the DIA.NE controller to shut down the engine automatically; myPlant records the event and sends a notification.
- Bearing Vibration Monitoring
Bearing vibration monitoring - continuous monitoring of the vibration level of the crankshaft main bearings and generator bearings. Rising vibration indicates the onset of bearing wear, rotor imbalance or loosened fasteners. myPlant tracks vibration trends and warns of abnormal increases well before the alarm setpoint is reached, so that bearing replacement can be scheduled for a planned shutdown.
- Cylinder-by-Cylinder Knock Monitoring
Cylinder-by-cylinder knock monitoring - real-time monitoring of the knock level in each cylinder of a Jenbacher engine using knock sensors. myPlant displays a knock distribution map across the cylinders and records trends. Uneven knock distribution points to a problem with a specific cylinder: a faulty spark plug, a clogged prechamber gas valve or uneven gas distribution.
Controllers and Integration
- DIA.NE XT3
DIA.NE XT3 - the 3rd-generation version of the Jenbacher gas engine controller. It was installed on Jenbacher Type 2, 3, 4 and 6 engines from approximately 2008 to 2016. It is fully compatible with the myPlant platform and supports all remote monitoring and control functions. KTS Engineering services units with DIA.NE XT3 and upgrades them to XT4 where needed.
Related terms: DIA.NE XT4 · ESM2
- DIA.NE XT4
DIA.NE XT4 - the current version of the Jenbacher gas engine controller. It has been installed on all new Jenbacher engines since 2016. Compared with XT3, it has an extended set of diagnostic functions, more precise control and broader integration with myPlant. It supports remote access via myPlant with separate access levels for the operator, KTS Engineering engineers and INNIO specialists.
Synonyms: DIA.NE · Jenbacher controller · XT4
- ESM2 and myPlant Compatibility
ESM2 (Engine Safety Module 2) - the controller of earlier Jenbacher engine series (up to 2008-2010), the predecessor of DIA.NE XT3. ESM2 has no direct built-in integration with myPlant; connecting such units to the monitoring platform requires an additional gateway device. KTS Engineering both connects ESM2 units to myPlant and upgrades them by replacing ESM2 with DIA.NE XT4.
- WEMS (Waukesha Engine Management System)
WEMS (Waukesha Engine Management System) - the engine management system for Waukesha engines, similar to DIA.NE for Jenbacher. Current versions of WEMS support integration with the myPlant platform for remote monitoring of Waukesha units. This allows customers who operate both Jenbacher and Waukesha units to monitor their entire fleet through a single myPlant interface.
myPlant is INNIO's cloud platform for remote monitoring and control of Jenbacher and Waukesha gas engine gensets. It provides 24/7 real-time monitoring, predictive diagnostics, alarm notifications and remote access to the DIA.NE controller. It is available in a web browser and as an iOS/Android mobile app.
myPlant APM analyzes trends in 300+ engine parameters: temperatures, pressures, vibration, knock and oil condition. Predictive algorithms detect deviations several days before a possible failure, allowing KTS Engineering to schedule a service visit in advance and prevent an emergency shutdown.