Fuels and Gases for Gas Engine Gensets: Terms and Definitions

This section contains terms related to the gaseous fuels used in gas engine gensets: natural gas, biogas, landfill gas, coal mine methane, associated petroleum gas and sewage gas. It also covers gas properties, biogas energy and gas treatment. Compiled by the engineers of KTS Engineering.

Types of Gaseous Fuel

Natural Gas

Natural gas - a combustible gas of natural origin produced from gas and gas condensate fields. Its main component is methane (CH4) at 85-99%. Lower heating value: 8,000-9,500 kcal/m³ (33-40 MJ/m³). Pipeline-quality natural gas has a methane number of 70-80 and above, which ensures stable operation of Jenbacher and Waukesha gas engines without special adaptation. The gas supply pressure to the engine is 50-500 mbar depending on the type of unit.

Related terms: methane number · LHV / net calorific value

Biogas

Biogas - a combustible gas produced by anaerobic digestion of organic waste. Composition: methane CH4 (50-75%), carbon dioxide CO2 (25-45%), and traces of H2S, nitrogen, oxygen and water vapor. Lower heating value: 4,500-6,500 kcal/m³. Biogas has a methane number of 130-140, giving it high knock resistance. Before being fed to a gas engine, biogas undergoes desulfurization, drying and siloxane removal.

Related terms: anaerobic digestion · H2S · siloxanes

Biomethane

Biomethane - purified biogas with a methane content of 95-99%, equivalent in composition to pipeline natural gas. It is produced from biogas by upgrading, i.e. removing CO2 and trace impurities. Biomethane can be injected directly into the gas grid or used as a vehicle fuel (bio-CNG - Renewable Natural Gas, RNG). Selling biomethane to the grid generates additional revenue for biogas projects.

Synonyms: upgraded biogas · RNG (Renewable Natural Gas)

Landfill Gas (LFG)

Landfill gas (LFG) - a combustible gas produced by the decomposition of the organic fraction of municipal solid waste (MSW) in landfills. Composition: methane CH4 (35-60%), CO2 (35-45%), and traces of organic compounds, H2S and siloxanes. Lower heating value: 3,500-6,000 kcal/m³. Methane number: 120-140. It requires an active gas collection system and drying before being fed to the engine. KTS Engineering case study, LNK landfill in Kropyvnytskyi: 38 wells, €629,412 in annual revenue.

Synonyms: MSW landfill gas · LFG

Coal Mine Methane (CMM)

Coal mine methane (CMM) - methane released from coal seams during coal mining. It is extracted by mine degasification systems and has a variable composition: the CH4 content ranges from 30% to 95% depending on the mining stage and seam depth. Special versions of Jenbacher gas engines run on CMM with as little as 30% methane. Utilizing coal mine methane addresses both an energy challenge (power and heat supply for the mine) and an environmental one (methane is a greenhouse gas with 21× the warming potential of CO2).

Synonyms: mine gas · CMM

Associated Petroleum Gas (APG)

Associated petroleum gas (APG) - gas dissolved in crude oil and released during oil production and primary processing. Composition: methane CH4 (40-80%), ethane C2H6, propane C3H8, butane C4H10 and heavier hydrocarbons. The high content of heavy hydrocarbons lowers the methane number of APG to 30-60, which requires special gas engine tuning or the use of Waukesha VGF series engines. Historically it was flared; utilizing APG in cogeneration is economically attractive and required by environmental legislation.

Synonyms: APG · associated gas · flare gas · Flare Gas

Flare Gas

Flare gas - surplus gas burned in a flare at oil wells, refineries or chemical plants. As a rule, it is APG or process gas that cannot be used immediately. Flaring is inefficient: most of the energy is lost, and CO2 and soot emissions cause environmental damage. Installing a gas engine power plant based on Waukesha or Jenbacher units makes it possible to utilize flare gas and generate electricity.

Synonyms: flared gas · flared APG · Associated Petroleum Gas (APG)

Sewage Gas

Sewage gas (wastewater gas) - biogas produced by anaerobic digestion of sewage sludge at wastewater treatment plants. Composition: CH4 60-70%, CO2 30-40%, traces of H2S. Lower heating value: 5,500-6,500 kcal/m³. Sewage gas is utilized in a cogeneration plant to produce electricity and heat; the heat is returned to the digester to maintain the digestion temperature (37-55°C). Cogeneration allows a water utility to cover 50-70% of its own electricity needs.

Synonyms: Wastewater gas · WWTP biogas

Syngas (Synthesis Gas)

Syngas (synthesis gas) - a combustible gas produced by gasification of solid fuels (coal, biomass) or partial oxidation of hydrocarbons. Composition: CO (20-30%), H2 (20-40%), CH4 (5-15%), CO2, N2. Its lower heating value is much lower than that of natural gas (1,500-3,500 kcal/m³). To run Jenbacher gas engines on syngas, a special low-calorific gas version with a modified gas path is used.

Hydrogen (H2)

Hydrogen (H2) - a colorless, odorless combustible gas regarded as a promising energy fuel with zero CO2 emissions when burned. The lower heating value of hydrogen is 2,860 kcal/m³ (much lower than natural gas on a volume basis). Jenbacher gas engines in the Hydrogen Ready version can run on natural gas / H2 blends with up to 25% H2 without modification and, after retrofitting, on up to 100% H2. KTS Engineering supplies Jenbacher Hydrogen Ready engines.

Synonyms: H2 · green hydrogen · hydrogen fuel

Coke Oven Gas

Coke oven gas - a by-product of producing coke from hard coal at 900-1,100°C. Composition: H2 (50-60%), CH4 (25-30%), CO (5-8%), CO2, N2. Lower heating value: 4,000-4,500 kcal/m³. Coke oven gas is a valuable energy resource for steel plants. Special versions of Jenbacher gas engines (low-calorific gas) make it possible to utilize coke oven gas for the power and heat supply of a coke plant.

Gas Properties

Lower Heating Value (LHV)

Lower heating value (LHV, also net calorific value, NCV) - the amount of heat released by the complete combustion of a unit volume or mass of gas, excluding the heat of condensation of the water vapor in the combustion products. It is the main parameter for calculating the output and efficiency of a gas engine. For natural gas, LHV ≈ 8,000-9,500 kcal/m³; for biogas, 4,500-6,500 kcal/m³; for landfill gas, 3,500-5,500 kcal/m³. Jenbacher engine ratings are specified at LHV = 8,500 kcal/m³.

Synonyms: LHV · net calorific value (NCV)

Methane Number (MN)

Methane number (MN) - a measure of a gaseous fuel's resistance to knocking, determined in a standard test engine by a method similar to the octane number for liquid fuels. Pure methane CH4 has MN = 100; pure hydrogen H2 has MN = 0; biogas MN 120-140; natural gas MN 70-80; APG with heavy hydrocarbons MN 30-60. Standard Jenbacher engines require MN ≥ 70. At a low MN, the DIA.NE controller automatically reduces load to prevent knock.

Synonym: MN

Wobbe Index

Wobbe Index (WI) - a measure of the interchangeability of fuel gases, calculated as the lower heating value divided by the square root of the gas's relative density. The Wobbe index determines the heat input of a burner at a given pressure: gases with the same WI are interchangeable without changing the burner settings. For natural gas, WI = 40-55 MJ/m³; for biogas, 18-26 MJ/m³. It is used in pipeline gas quality standards and in the design of genset gas systems.

Synonyms: WI · Wobbe number

Hydrogen Sulfide Content (H2S)

Hydrogen sulfide content (H2S) in biogas and landfill gas - the concentration of a corrosive and toxic gas formed by the decomposition of sulfur-containing organic matter. The maximum H2S content for Jenbacher engines is 0.05% (500 ppm). Above this threshold, biogas desulfurization is required. Elevated H2S accelerates corrosion of gas path components and shortens oil life. It is monitored by an online analyzer in the gas treatment unit.

Siloxanes in Biogas

Siloxanes - organosilicon compounds present in biogas from sewage sludge and in biogas from MSW landfills. When burned in the cylinders of a gas engine, siloxanes form solid silicon dioxide (SiO2) crystals that deposit on pistons, valves, spark plugs and prechambers. SiO2 deposits cause abrasive wear and drastically shorten engine life. The maximum siloxane content for Jenbacher engines is less than 1 mg/m³. Siloxanes are removed by adsorption on activated carbon or silica gel in the gas treatment unit.

Gas Dew Point

Gas dew point - the temperature at which the moisture contained in a gas begins to condense. Condensate in the gas line and the engine gas path causes corrosion, clogged injectors and unstable ignition. Biogas and landfill gas are usually saturated with water vapor and must be dried to a dew point of -5°C or lower. It is monitored with a moisture analyzer or by calculation.

Biogas Energy

Biogas Plant

Biogas plant - a process facility that produces biogas from organic waste and uses it to generate electricity and heat. It includes a feedstock reception area, an anaerobic digestion reactor (digester), a biogas treatment system (gas treatment unit) and a biogas gas engine power plant. KTS Engineering designs and builds turnkey biogas plants, including the largest biogas complex in Europe - the Teofipol complex, 26.1 MW.

Synonyms: biogas power plant · biogas facility · biogas complex

Anaerobic Digestion

Anaerobic digestion - a biochemical process in which microorganisms break down organic matter in the absence of oxygen, releasing biogas. It takes place in a digester at 37-40°C (mesophilic mode) or 50-55°C (thermophilic mode). The rate and yield of biogas depend on the composition of the feedstock, the temperature and the retention time of the organic matter in the reactor. KTS Engineering has completed dozens of biogas projects in Ukraine's agricultural sector.

Synonyms: anaerobic fermentation · methane fermentation · AD

Digester

Digester - a sealed reactor for the anaerobic digestion of organic waste. As a rule, it is a cylindrical reinforced concrete or steel tank with a mixing system, feedstock heating and a gas dome for collecting biogas. Digester volumes range from several hundred to tens of thousands of m³ depending on the capacity of the biogas plant. The retention time of the feedstock in the digester is 20-40 days.

Synonyms: anaerobic reactor · biogas reactor · fermenter

Digestate

Digestate - the residue left after anaerobic digestion in a digester: organic matter rich in nutrients (nitrogen, phosphorus, potassium). It is used as a high-quality organic fertilizer - a valuable product of biogas projects alongside electricity and heat. Digestate is much better than raw manure: the nutrients are converted into a form readily available to plants, odor is reduced and pathogens are inactivated.

Synonyms: digested slurry · digested sludge · digestate

Biogas Feedstock (Substrate)

Biogas feedstock (substrate) - the organic raw material fed into a digester for anaerobic digestion. The main types of feedstock:

  • cattle, pig and poultry manure;
  • silage (maize, cereal);
  • organic waste from food production;
  • sewage sludge;
  • energy crops (Jerusalem artichoke, beet).

The choice of feedstock determines the methane potential and the economics of the project. The most popular co-substrate in Ukraine is maize silage, thanks to its high biogas yield and availability.

Methane Potential

Methane potential (BMP - Biochemical Methane Potential) - the maximum amount of methane that can be obtained from a unit mass of organic matter by anaerobic digestion. It is measured in L CH4 / kg VS (volatile solids, i.e. organic dry matter). Cattle manure - 200-250 L/kg; maize silage - 300-400 L/kg; food processing fat - 750-900 L/kg. It is determined by a laboratory BMP test and is the basis for designing a biogas plant.

Feed-in Tariff for Biogas

Feed-in tariff for biogas ("green tariff") - a special support purchase price for electricity from renewable sources (including biogas) at which the state is obliged to buy all the electricity produced by a biogas plant. In Ukraine, the feed-in tariff for biogas was set in euro cents per kWh and was the key driver of biogas project economics in 2012-2020. After 2020, the support model changed; please check the current terms with KTS Engineering.

Landfill Gas (LFG)

MSW Landfill Degasification

MSW landfill degasification - a system for the forced extraction of landfill gas from the body of a landfill. Active degasification includes a network of vertical and horizontal gas extraction wells, a collection pipe network, blowers to create a vacuum, and gas cleaning units. Landfill degasification is mandatory under sanitary regulations and pays off economically: landfill gas is a free fuel. KTS Engineering completed the degasification project at the LNK landfill in Kropyvnytskyi with 38 wells (2019).

Landfill Gas Well

Landfill gas well - a vertical perforated pipe sunk into the body of an MSW landfill to extract landfill gas. The well diameter is 200-400 mm, and it extends down to the bottom layer of waste. A gravel pack is placed around the perforated section of the well for even gas extraction. The number and layout of wells are determined from a topographic survey of the landfill and gas potential measurements. KTS Engineering installed 38 wells at the LNK landfill (Kropyvnytskyi).

Landfill Gas Collection Header

Landfill gas collection header - a pipe network that transports landfill gas from the wells to the gas treatment unit and on to the gas engine genset. The header is made of PE100 polyethylene pipes laid in the ground across the landfill body. Its design includes condensate traps to remove the moisture that condenses in the pipes as the gas cools.

MSW Landfill Gas Potential

MSW landfill gas potential - the estimated landfill gas flow rate and the recoverable gas resource, determined from the volume and composition of the buried waste, the age of the landfill and the climate. Gas generation models (LandGEM, FOD) are used for preliminary estimates. Accurate measurements are taken at several test wells. KTS Engineering prepares feasibility studies for landfill gas projects, including calculations of gas potential, CAPEX and payback period.

Gas Treatment

Gas Treatment Unit

Gas treatment unit (gas conditioning skid) - a packaged unit that treats biogas or landfill gas to the parameters acceptable for a gas engine. Typical composition of a biogas treatment unit:

  • a separator for coarse removal of moisture and solid particles;
  • a desulfurization unit (H2S removal);
  • a gas cooler-dryer (moisture removal, dew point reduction);
  • an activated carbon filter (removal of siloxanes and organic impurities);
  • a gas meter and a gas analyzer.
Biogas Desulfurization

Biogas desulfurization - removal of hydrogen sulfide from biogas to a level acceptable for a gas engine. Three methods are used: (1) biological desulfurization - injecting air into the digester's gas dome so that bacteria oxidize the H2S (economical, reduces H2S to 200-500 ppm); (2) chemical - dosing iron chloride FeCl2 into the digester to precipitate FeS (down to 100 ppm); (3) adsorption on activated carbon - for fine cleaning down to 5-20 ppm.

Gas Drying

Gas drying - reducing the moisture content of biogas or landfill gas to a safe level by cooling the gas below its dew point and separating the condensed moisture. The standard solution is a refrigerated dryer (cooling to 2-5°C). For deeper drying, molecular sieve adsorption dryers are used. Adequate drying is critical to prevent corrosion of the engine gas path and deposits in the injectors.

Gas Analyzer

Gas analyzer - an instrument for continuous measurement of gas composition in the flow. In biogas plants, it monitors the content of CH4 and CO2 (infrared sensor), H2S (electrochemical sensor) and O2. Data from the online analyzer is used by the DIA.NE control system to adjust engine operation when the gas composition changes.

Synonyms: gas monitor · online gas analyzer · gas chromatograph (for laboratory analysis)

Gas Compression

Gas compression - raising the gas pressure with a gas compressor (booster) to the working pressure required for the engine gas path. Landfill gas extracted by the degasification system at below-atmospheric pressure must be compressed to 50-300 mbar before it is fed to the genset. Biogas from digester domes usually has a pressure of 10-50 mbar and also needs compression.